display_menu: cleanup, add things

This commit is contained in:
Konstantin Koslowski 2021-08-11 17:03:35 +02:00
parent d685c92794
commit 2dad4e40e9
3 changed files with 132 additions and 2 deletions

127
display_menu.cfg Normal file
View file

@ -0,0 +1,127 @@
##
# Display Menu definition #
##
# Removed items
[menu __main __octoprint]
type: disabled
## PreHeat
[menu __main __temp __preheat_pla]
type: disabled
[menu __main __temp __preheat_abs]
type: disabled
## use own load and unload macro
[menu __main __filament __loadf]
type: disabled
[menu __main __filament __loads]
type: disabled
[menu __main __filament __unloadf]
type: disabled
[menu __main __filament __unloads]
type: disabled
## Delta Calibration
[menu __main __setup __calib __delta_calib_auto]
type: disabled
[menu __main __setup __calib __delta_calib_man]
type: disabled
# Added Items to the Stock menu #
[menu __main __filament __load]
type: command
name: Load Filament
gcode:
FILAMENT_LOAD
[menu __main __filament __unload]
type: command
name: Unload Filament
gcode:
FILAMENT_UNLOAD
## Probe & Endstop Z-Offset calibration
[menu __main __setup __calib __Z_offset]
type: list
enable: {not printer.idle_timeout.state == "Printing"}
name: Z offset
[menu __main __setup __calib __Z_offset __start]
type: input
enable: {not printer.idle_timeout.state == "Printing"}
name: Do {['None','Probe','Endstop'][menu.input|int]}
input: 0
input_min: 0
input_max: 2
input_step: 1
gcode:
{%- if menu.event == 'long_click' -%}
{menu.back()}
{%- if menu.input|int == 1 -%}
{action_respond_info("Start Probe calibration")}
PROBE_CALIBRATE
{%- elif menu.input|int == 2 -%}
{action_respond_info(" Start Z-Endstop calibration")}
Z_ENDSTOP_CALIBRATE
{%- endif -%}
{%- endif -%}
[menu __main __setup __calib __Z_offset __move_z]
type: input
name: Move Z: {'%03.2f' % menu.input}
input: {printer.gcode_move.gcode_position.z}
input_step: 1
realtime: True
gcode:
{%- if menu.event == 'change' -%}
G1 Z{'%.2f' % menu.input}
{%- elif menu.event == 'long_click' -%}
G1 Z{'%.2f' % menu.input}
SAVE_GCODE_STATE NAME=__move__axis
G91
G1 Z2
G1 Z-2
RESTORE_GCODE_STATE NAME=__move__axis
{%- endif -%}
[menu __main __setup __calib __Z_offset __test_z]
type: input
name: Test Z: {['++','+','+.01','+.05','+.1','+.5','-.5','-.1','-.05','-.01','-','--'][menu.input|int]}
input: 5
input_min: 0
input_max: 11
input_step: 1
gcode:
{%- if menu.event == 'long_click' -%}
TESTZ Z={['++','+','+.01','+.05','+.1','+.5','-.5','-.1','-.05','-.01','-','--'][menu.input|int]}
{%- endif -%}
[menu __main __setup __calib __Z_offset __test_z_live]
type: input
name: Test Z : {'%03.3f' % menu.input}
input: 0
input_min: -5.0
input_max: 5.0
input_step: 0.01
realtime: True
gcode:
{%- if menu.event == 'long_click' -%}
TESTZ Z={'%.3f' % menu.input}
{%- endif -%}
[menu __main __setup __calib __Z_offset __accept]
type: command
name: Accept
gcode: ACCEPT
[menu __main __setup __calib __Z_offset __abort]
type: command
name: Abort
gcode: ABORT

View file

@ -116,7 +116,7 @@ gcode:
TURN_OFF_HEATERS TURN_OFF_HEATERS
CANCEL_PRINT_BASE CANCEL_PRINT_BASE
[gcode_macro UNLOAD] [gcode_macro FILAMENT_UNLOAD]
description: unload filament description: unload filament
gcode: gcode:
{% if printer.extruder.can_extrude|lower == 'true' %} {% if printer.extruder.can_extrude|lower == 'true' %}
@ -127,7 +127,7 @@ gcode:
{action_respond_info("extruder not hot enough")} {action_respond_info("extruder not hot enough")}
{% endif %} {% endif %}
[gcode_macro LOAD] [gcode_macro FILAMENT_LOAD]
description: load filament description: load filament
gcode: gcode:
{% if printer.extruder.can_extrude|lower == 'true' %} {% if printer.extruder.can_extrude|lower == 'true' %}

View file

@ -24,6 +24,9 @@ path: ~/gcode_files
## macros ## macros
[include macros.cfg] [include macros.cfg]
## display menu
[include display_menu.cfg]
## web ## web
[pause_resume] [pause_resume]