v2.4: add chamber thermistor
This commit is contained in:
		
							parent
							
								
									fda0feede8
								
							
						
					
					
						commit
						309d95a5e8
					
				
					 1 changed files with 16 additions and 0 deletions
				
			
		
							
								
								
									
										16
									
								
								printer.cfg
									
										
									
									
									
								
							
							
						
						
									
										16
									
								
								printer.cfg
									
										
									
									
									
								
							|  | @ -365,6 +365,22 @@ heater_temp: 45.0 | |||
| # 	Homing and Gantry Adjustment Routines | ||||
| ##################################################################### | ||||
| 
 | ||||
| ##################################################################### | ||||
| #	Enclosure Temp Sensor Section | ||||
| ##################################################################### | ||||
| [thermistor chamber_temp] | ||||
| temperature1: 25 | ||||
| resistance1: 10000 | ||||
| beta: 3950 | ||||
| 
 | ||||
| 
 | ||||
| [temperature_sensor enclosure_temp] | ||||
| sensor_type: chamber_temp | ||||
| sensor_pin: PF5 | ||||
| min_temp: 0 | ||||
| max_temp: 100 | ||||
| gcode_id: C | ||||
| 
 | ||||
| [idle_timeout] | ||||
| timeout: 1800 | ||||
| 
 | ||||
|  |  | |||