##################################################################### # Z Calibration ##################################################################### [z_calibration] # The X and Y coordinates (in mm) for clicking the nozzle on the # Z endstop. probe_nozzle_x: 208 probe_nozzle_y: 305 # The X and Y coordinates (in mm) for clicking the probe's switch # on the Z endstop. probe_switch_x: 201 probe_switch_y: 284 # The X and Y coordinates (in mm) for probing on the print surface # (e.g. the center point) These coordinates will be adapted by the # probe's X and Y offsets. The default is the relative_reference_index # of the configured bed_mesh. It will raise an error if there is no # probe_bed site and no bed_mesh with a relative_reference_index # configured. probe_bed_x: 150 probe_bed_y: 150 # The trigger point offset of the used mag-probe switch. # This needs to be fined out manually. More on this later # in this section.. switch_offset: 0.42 # The maximum allowed deviation of the calculated offset. # If the offset exceeds this value, it will stop! # The default is 1.0 mm. max_deviation: 1.5 # The number of times to probe each point. The probed z-values # will be averaged. The default is from the probe's configuration. #samples: default from "probe:samples" section # The maximum Z distance (in mm) that a sample may differ from other # samples. The default is from the probe's configuration. #samples_tolerance: default from "probe:samples_tolerance" section # The number of times to retry if a sample is found that exceeds # samples_tolerance. The default is from the probe's configuration. #samples_tolerance_retries: default from "probe:samples_tolerance_retries" section # The calculation method when sampling more than once - either # "median" or "average". The default is from the probe's configuration. #samples_result: default from "probe:samples_result" section # The distance in mm to move up before moving to the next # position. The default is two times the z_offset from the probe's # configuration. clearance: 7.5 #position_min: default from "stepper_z:position_min" section. # The moving speed in X and Y. The default is 50 mm/s. speed: 200 # Speed (in mm/s) of the Z axis when lifting the probe between # samples and clearance moves. The default is from the probe's # configuration. #lift_speed: default from "probe:lift_speed" section # The fast probing speed (in mm/s) used, when probing_first_fast # is activated. The default is from the Z rail configuration. #probing_speed: default from "stepper_z:homing_speed" section. # The slower speed (in mm/s) for probing the recorded samples. # The default is second_homing_speed of the Z rail configuration. #probing_second_speed: default from "stepper_z:second_homing_speed" section. # Distance to back off (in mm) before probing the next sample. # The default is homing_retract_dist from the Z rail configuration. #probing_retract_dist: default from "stepper_z:homing_retract_dist" section. # If true, the first probing is done faster by the probing speed. # This is to get faster down and the result is not recorded as a # probing sample. The default is false. probing_first_fast: true # If true, the first probing is done faster by the probing speed. # This is to get faster down and the result is not recorded as a # probing sample. The default is false. start_gcode: DETACH_PROBE # A list of G-Code commands to execute prior to each calibration command. # See docs/Command_Templates.md for G-Code format. This can be used to # attach the probe. before_switch_gcode: ATTACH_PROBE # A list of G-Code commands to execute prior to each probing on the # mag-probe. See docs/Command_Templates.md for G-Code format. This can be # used to attach the probe after probing on the nozzle and before probing # on the mag-probe. end_gcode: DETACH_PROBE # A list of G-Code commands to execute after each calibration command. # See docs/Command_Templates.md for G-Code format. This can be used to # detach the probe afterwards. ##################################################################### ## With these settings, the probe is attached after probing the nozzle ## and before probing the switch !! ##################################################################### ## Otherwise, starting with the probe attached would be like this: start_gcode: ATTACH_PROBE #before_switch_gcode: ATTACH_PROBE end_gcode: DETACH_PROBE ##################################################################### ##################################################################### # Macros ##################################################################### ################################################################### # !!! Caution !!! # # This Macro is only needed if not using the start/end_gcode # properties to attach/detach the probe ################################################################### [gcode_macro CALIBRATE_Z] description: Automatically calibrates the nozzles offset to the print surface and dock/undock MagProbe rename_existing: CALIBRATE_Z_BASE gcode: ##### get user defines ##### {% set z_hop = printer['gcode_macro _USER_VARIABLE'].probe_z_min|float %} ##### get toolhead parameters ##### {% set act_z = printer.gcode_move.gcode_position.z|float %} #### end of definitions ##### ## reduce current of motors _SET_ACC VAL=HOME _SET_CURRENT VAL=HOME _CG28 RESET_SETTINGS=false {% if act_z < z_hop %} G90 ; absolute positioning {action_respond_info("CALIBRATE_Z: High must be above %.2f" % z_hop)} G1 Z{z_hop} F900 ; move head up {% endif %} #ATTACH_PROBE CALIBRATE_Z_BASE #DETACH_PROBE {% if params.RESET_SETTINGS|default('true') == 'true' %} ## return to org current settings _SET_CURRENT _SET_ACC {% endif %}